① Specially designed fixtures, quick and convenient replacement of workpieces, suitable for various directions of air conditioning piping
② Each vacuum box can detect multiple workpieces, and multiple vacuum boxes work together
③ Capable of identifying specific leaked workpieces
Leakage rate: ≤ 2g/year
Test pressure: Low pressure 5~25bar, high pressure 20~40bar
Beat: 50-70S/box
Box door opening and closing method: inclined up and down
Change time: ≤ 10MIN
Control mode: PLC control, touch screen operation